PrimeSIL AGP Chiral
PrimeSIL AGP Chiral

PrimeSIL AGP Chiral

MOQ : 10 Pieces

PrimeSIL AGP Chiral Specification

  • Speed Range
  • Typical flow rate 0.2 - 1.0 mL/min
  • Features
  • High reproducibility, high capacity, excellent chiral selectivity, suitable for reversed-phase and polar organic modes
  • Shape
  • Columnar
  • Temperature Resistance
  • Recommended 4C to 40C
  • Control Type
  • Manual/Compatible with standard HPLC systems
  • Accuracy
  • High resolution for enantiomeric separation
  • Type
  • Chiral HPLC Column
  • Dimension (L*W*H)
  • 150 mm x 4.0 mm (other sizes available)
  • Equipment Type
  • HPLC Chiral Column
  • Equipment Materials
  • Stainless Steel Column with AGP (alpha-1-acid glycoprotein) as stationary phase
  • Material
  • High purity silica with covalently immobilized AGP protein
  • Application
  • Chiral separation of pharmaceutical compounds, enantiomeric purity testing, quality control in drug development
  • Compatible Detectors
  • UV, MS, FLD, others as per HPLC system
  • pH Range
  • 4.5 - 7.5 (optimal stability and protein activity)
  • Maximum Pressure
  • 300 bar (depending on size and system)
  • End-capping
  • Yes
  • USP Code
  • L41 (Chiral stationary phase)
  • Stationary Phase
  • Alpha-1-acid glycoprotein (AGP) protein
  • Pore Size
  • 120 A
  • Solvent Compatibility
  • Aqueous buffers, methanol, acetonitrile (as recommended by manufacturer)
  • Particle Size
  • 5 m
 

PrimeSIL AGP Chiral Trade Information

  • Minimum Order Quantity
  • 10 Pieces
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 7 Days
  • Main Domestic Market
  • All India
 

About PrimeSIL AGP Chiral



Elevate your laboratory prowess with the illustrious PrimeSIL AGP Chiral HPLC Column-engineered for the discerning scientist striving for enlightened enantiomeric separations. With a high-capacity stationary phase of covalently immobilized AGP protein on pure silica, this HOT DEAL ensures high reproducibility and exceptional chiral selectivity for pharmaceutical quality control. Suitable for UV, MS, and FLD detectors, this stainless steel column delivers high resolution in a recommended pH range of 4.5-7.5. Add to Cart now and experience the best in chiral separation science. Get It Now for optimal results!

PrimeSIL AGP Chiral: Superior Usage and Key Application Insight

Designed for HPLC chiral column applications, the PrimeSIL AGP Chiral stands out for its manual compatibility and seamless integration into standard HPLC systems. It excels in enantiomeric purity testing, chiral separation of pharmaceutical compounds, and rigorous drug development quality control. Featuring high purity silica with immobilized AGP protein, its material is renowned for delivering optimal stability and activity, making it the best choice for laboratories demanding high-capacity, high-selectivity analyses.


Export Markets, Domestic Reach, and Sample Details of PrimeSIL AGP Chiral

PrimeSIL AGP Chiral is highly sought after across prominent export markets, with distributors, exporters, and suppliers in India facilitating global reach. Expenditure estimates and purchase orders can be customized according to shipment quantity, ensuring smooth procurement. Samples are available for evaluation, supporting informed decision-making. The main domestic market remains robust, catering to the growing demand for superior analytical solutions in Indian laboratories while maintaining high international standards.


FAQ's of PrimeSIL AGP Chiral:


Q: How is the PrimeSIL AGP Chiral HPLC column best utilized in scientific applications?

A: The PrimeSIL AGP Chiral column is best utilized for enantiomeric separation in pharmaceutical research, enantiomeric purity testing, and quality control processes. Its high-resolution capability and outstanding chiral selectivity make it ideal for laboratories focused on drug development and analytical chemistry.

Q: What materials and features distinguish the PrimeSIL AGP Chiral column?

A: This column features high purity silica with a covalently immobilized alpha-1-acid glycoprotein (AGP) stationary phase, stainless steel construction, and end-capping for optimal stability. Its high capacity and excellent reproducibility set it apart for meticulous analytical work.

Q: When should laboratories consider using PrimeSIL AGP Chiral for their analysis?

A: Laboratories should consider the PrimeSIL AGP Chiral column when they require highly accurate chiral separation, particularly for pharmaceutical compounds, and need robust performance between pH 4.5 and 7.5 with compatible detectors like UV, MS, and FLD.

Q: Where can PrimeSIL AGP Chiral be exported or purchased?

A: PrimeSIL AGP Chiral columns are distributed, exported, and supplied globally, with a strong presence in India's domestic and main export markets. Purchase orders and expenditure estimates can be discussed directly with certified distributors or manufacturers.

Q: What is the recommended usage process for optimal results with PrimeSIL AGP Chiral?

A: For optimal results, operate the column within a flow rate of 0.2 - 1.0 mL/min, use aqueous buffers or recommended solvents, maintain temperature between 4C and 40C, and adhere to the ideal pH range to ensure protein activity and stability.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in PrimeSIL Chiral Category

PrimeSIL Chiral

PrimeSIL Chiral

Minimum Order Quantity : 10 Pieces

Shape : Cylindrical

Features : High chiral selectivity, excellent peak shape, reproducible results

Equipment Type : Chromatography Column

Temperature Resistance : Up to 40C

Equipment Materials : Stainless Steel



Back to top