PrimeSIL C8 HS HPLC Columns
PrimeSIL C8 HS HPLC Columns

PrimeSIL C8 HS HPLC Columns

MOQ : 10 Pieces

PrimeSIL C8 HS HPLC Columns Specification

  • Features
  • High surface coverage, excellent reproducibility, enhanced retention, high stability and durability, suitable for acidic, neutral and basic compounds
  • Shape
  • Cylindrical
  • Type
  • C8 Reversed Phase HPLC Column
  • Dimension (L*W*H)
  • 4.6 x 250 mm
  • Equipment Type
  • HPLC Column
  • Equipment Materials
  • Stainless Steel Column
  • Material
  • High-purity silica, C8 bonded phase
  • Application
  • High Performance Liquid Chromatography (HPLC) for pharmaceuticals, environmental, chemical, and food analysis
  • Compatibility
  • Compatible with most brands of HPLC instruments
  • pH Range
  • 2-8
  • Carbon Load
  • 8%
  • Particle Size
  • 5 m
  • Column Length
  • 250 mm
  • USP Code
  • L7
  • Endcapping
  • Double Endcapped
  • Column Inner Diameter
  • 4.6 mm
  • Pore Size
  • 120 A
  • Maximum Pressure
  • 400 bar
 

PrimeSIL C8 HS HPLC Columns Trade Information

  • Minimum Order Quantity
  • 10 Pieces
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 7 Days
  • Main Domestic Market
  • All India
 

About PrimeSIL C8 HS HPLC Columns



Ending Soon: Don't miss the spectacular clearance on PrimeSIL C8 HS HPLC Columns! Engineered with ineffable precision, these dominant columns boast a 5 m particle size, 120 A pore size, and 8% carbon load, ensuring high stability for a range of analyses. Shop now to secure a double endcapped, high-purity silica C8 phase column designed for superior retention and reproducibility. Compatible with most HPLC systems and built using a robust stainless steel body, PrimeSIL guarantees high durability and performance for pharmaceuticals, chemicals, foods, and environmental applications.

Versatility and Competitive Edge for Modern Analysis

PrimeSIL C8 HS HPLC Columns offer wide-ranging applicability across pharmaceuticals, food safety, environmental testing, and chemical research. Their superior surface coverage and enhanced retention provide a competitive edge, especially when diverse sample matrices are involved. The robust C8 bonded phase efficiently separates acidic, neutral, and basic substances. These columns perform remarkably in both gradient and isocratic applications, ensuring consistent results in labs aiming for advanced, high-efficiency separations and maximum productivity.


Convenient Payment, Fast Dispatch, & Certifications

PrimeSIL C8 HS HPLC Columns are offered with flexible payment terms and a transparent sample policy. Stock is ready for immediate shipment-quick dispatch minimizes your downtime and optimizes workflow. Customers can be assured of certified quality, ensuring compliance with global standards. The outlay for these columns is justified by their durability and proven results, making them an excellent investment for laboratories requiring both reliability and regulatory confidence.


FAQ's of PrimeSIL C8 HS HPLC Columns:


Q: How do I use the PrimeSIL C8 HS HPLC Column with my existing HPLC system?

A: The PrimeSIL C8 HS HPLC Column is designed for broad compatibility, allowing seamless integration with most brands of HPLC instruments. Simply follow your system manufacturer's instructions for column installation and equilibration.

Q: What are the main benefits of using PrimeSIL C8 HS HPLC Columns in analytical applications?

A: These columns deliver excellent reproducibility, enhanced retention, high surface coverage, and superior stability, making them ideal for separating a wide range of compounds across pharmaceuticals, chemicals, and environmental samples.

Q: Where can I use PrimeSIL C8 HS HPLC Columns?

A: PrimeSIL C8 HS HPLC Columns are widely employed in laboratories specializing in pharmaceuticals, food analysis, environmental testing, and chemical research, offering flexibility for various analytical media.

Q: What is the process for ordering and receiving a PrimeSIL C8 HS HPLC Column?

A: Ordering is straightforward-contact your distributor, supplier, or trader. Stock is typically ready, and quick dispatch ensures you receive your columns promptly upon completion of the purchasing process.

Q: When is the best time to purchase the PrimeSIL C8 HS HPLC Columns?

A: With the current clearance and the offer ending soon, now is the ideal time to secure these high-performance columns at a competitive price point.

Q: How is the quality of the PrimeSIL C8 HS HPLC Columns assured?

A: Each column comes with certifications confirming compliance with international quality standards, ensuring consistent and reliable performance in demanding laboratory environments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in PrimeSIL HPLC Columns Category

PrimeSIL ODS HPLC Columns

PrimeSIL ODS HPLC Columns

Minimum Order Quantity : 10 Pieces

Equipment Materials : 316 Stainless Steel Column Housing

Material : High Purity Spherical Silica Gel

Dimension (L*W*H) : 150 x 4.6 mm

Shape : Cylindrical

Type : Other, C18 ODS Reversed Phase HPLC Column

PrimeSIL NH2 HPLC Columns

PrimeSIL NH2 HPLC Columns

Minimum Order Quantity : 10 Pieces

Equipment Materials : Stainless Steel Column Housing

Material : Silica Gel with Amino (NH2) Functional Group

Dimension (L*W*H) : 250 x 4.6 mm

Shape : Cylindrical

Type : Other, Analytical HPLC Column

Primesil C30 HPLC Columns

Primesil C30 HPLC Columns

Minimum Order Quantity : 10 Pieces

Equipment Materials : Stainless Steel Column Housing

Material : Bonded C30 Silica

Dimension (L*W*H) : 250 x 4.6 mm (other available sizes: 150 x 4.6 mm, 250 x 4.6 mm, 250 x 10 mm)

Shape : Cylindrical

Type : Other, HPLC Column

Primesil C8 HPH HPLC Columns

Primesil C8 HPH HPLC Columns

Minimum Order Quantity : 10 Pieces

Equipment Materials : Stainless Steel Column Body

Material : Silica with C8 (Octyl) Bonded Phase

Dimension (L*W*H) : 250 x 4.6 mm

Shape : Cylindrical

Type : Other, HPLC Column



Back to top