Primesil Diol HPLC Columns
Primesil Diol HPLC Columns

Primesil Diol HPLC Columns

MOQ : 10 Pieces

Primesil Diol HPLC Columns Specification

  • Shape
  • Cylindrical
  • Features
  • High column efficiency, excellent reproducibility, compatible with normal and HILIC mode
  • Accuracy
  • Particle size 5 m, 3 m available
  • Temperature Resistance
  • Recommended up to 60C
  • Type
  • Diol HPLC Column
  • Dimension (L*W*H)
  • 250 mm 4.6 mm i.d.
  • Equipment Type
  • HPLC Column
  • Equipment Materials
  • Stainless Steel Column Housing
  • Material
  • Silica-based, Diol-bonded Phase
  • Application
  • Analytical/Preparative HPLC - Normal Phase, Polar Compound Analysis, Carbohydrate Analysis
  • Capacity (Ltr)
  • Column Volume: approx. 4.2 mL (for 250 4.6 mm i.d.)
  • Mobile Phase Compatibility
  • Normal phase, HILIC, and reverse phase (with suitable solvents)
  • Particle Size
  • 3 m or 5 m
  • Connector Type
  • Standard HPLC end fittings (metal ferrule)
  • Surface Area
  • 330 m2/g
  • Pore Size
  • 120 A
  • USP L Column Code
  • L20 (Diol phase)
  • End-capping
  • No (bare diol phase)
  • pH Range
  • 2.0 - 8.0
  • Maximum Pressure
  • 400 bar
 

Primesil Diol HPLC Columns Trade Information

  • Minimum Order Quantity
  • 10 Pieces
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 7 Days
  • Main Domestic Market
  • All India
 

About Primesil Diol HPLC Columns



Discover the new release of Primesil Diol HPLC Columns-outstanding in analytical and preparative applications, now available at a deal you can't miss. These phenomenal columns offer particle sizes of 3 m or 5 m, and a generous pore size of 120 A with an expansive surface area of 330 m2/g. Engineered for the finest performance in normal phase, HILIC, and reversed phase chromatography, they withstand pressures up to 400 bar. End-capping-free, the bare diol phase ensures exceptional reproducibility and column efficiency. Find the best for polar compound analysis and carbohydrate separations-your finest HPLC partnership now in India!

Versatile Features and Diverse Applications

Primesil Diol HPLC Columns offer high column efficiency, robust temperature resistance up to 60C, and compatibility with various solvent systems. Perfect for plant extract analysis, these columns excel in analytical labs, pharma research, and food industries. Used as key tools for normal phase and HILIC methods, they are ideal for polar compound and carbohydrate examination. Their cylindrical stainless steel build and silica-based material ensure a durable, reliable solution for diverse testing needs.


Certifications, Payment, and Delivery for Export Markets

Our Primesil Diol HPLC Columns are crafted under stringent manufacturing standards and are ready for both domestic and export markets. Standard certifications ensure reliability and conformity. Payment terms are negotiable, providing expenditure flexibility with secure modes to suit your procurement process. Once the transaction is finalized, columns are carefully packed and handed over, typically ensuring prompt delivery time across global destinations. Acquire assured quality and seamless logistics with every order.


FAQ's of Primesil Diol HPLC Columns:


Q: How do Primesil Diol HPLC Columns benefit carbohydrate and polar compound analysis?

A: These columns are specifically designed for outstanding separation of polar compounds and carbohydrates due to their bare diol phase, delivering high efficiency and excellent reproducibility in both normal phase and HILIC modes.

Q: What applications are suitable for Primesil Diol HPLC Columns?

A: Ideal for analytical and preparative HPLC tasks, especially in pharmaceutical, food, and research labs, they are well-suited for normal phase, HILIC, and reversed phase chromatography (with proper solvents), supporting polar compound and carbohydrate analysis.

Q: Where are Primesil Diol HPLC Columns manufactured and distributed from?

A: They are manufactured, distributed, and exported from India, reaching both local and international markets through a robust supply and export system.

Q: What is the process for installing and using Primesil Diol HPLC Columns?

A: Installation uses standard HPLC end fittings (metal ferrules). For best results, flush the system with the chosen mobile phase, gradually condition the column, and ensure compatible solvent systems per your desired analytical method.

Q: When can I expect delivery after placing an order for Primesil Diol HPLC Columns?

A: Delivery times depend on your location and order volume; once payment is completed, columns are handed over for prompt shipping, ensuring minimal delay for both domestic and export customers.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in PrimeSIL HPLC Columns Category

Primesil ODS P HPLC Columns

Primesil ODS P HPLC Columns

Minimum Order Quantity : 10 Pieces

Features : High separation efficiency, endcapped ODS phase, excellent peak shape, high chemical stability

Application : Analytical separations and quantification by HPLC

Dimension (L*W*H) : 250 x 4.6 mm, 150 x 4.6 mm, 100 x 4.6 mm (other dimensions available)

Shape : Cylindrical

Equipment Materials : Stainless Steel Column Tube

PrimeSIL ODS HPLC Columns

PrimeSIL ODS HPLC Columns

Minimum Order Quantity : 10 Pieces

Features : Excellent Peak Symmetry, Low Back Pressure, High Stability, and Robust Performance

Application : Analytical, Pharmaceutical, Chemical, and Food Sample Analysis

Dimension (L*W*H) : 150 x 4.6 mm

Shape : Cylindrical

Equipment Materials : 316 Stainless Steel Column Housing

PrimeSIL RP 8 HPLC Columns

PrimeSIL RP 8 HPLC Columns

Minimum Order Quantity : 10 Pieces

Features : High efficiency, excellent peak symmetry, reproducible performance

Application : High Performance Liquid Chromatography (HPLC) separations

Dimension (L*W*H) : 250 mm x 4.6 mm

Shape : Cylindrical

Equipment Materials : Stainless Steel Column Housing

Primesil BDS C18 HPLC Columns

Primesil BDS C18 HPLC Columns

Minimum Order Quantity : 10 Pieces

Features : Basedeactivated silica, excellent peak shape, high chemical stability, enhanced performance for basic compounds

Application : HPLC analysis, pharmaceutical, environmental, food & chemical separations

Dimension (L*W*H) : 250 mm 4.6 mm

Shape : Cylindrical

Equipment Materials : Highpurity stainless steel column hardware



Back to top